Agreement of white-to-white measurements with the IOLMaster 700, Atlas 9000, and Sirius systems

2018

Current advances in ocular surgery require the evaluation of differences in automated white-to-white (WTW) measurements between systems. We aim to analyze three different commonly used devices in clinical practice: the IOLMaster 700, the Atlas 9000, and the Sirius.Ninety right eyes of ninety healthy subjects were included. Measurements of WTW distances were taken with each device for all subjects in the same session and by the same observer. Statistical comparison was carried out by means of the rANOVA procedure and the Bonferroni post-hoc test. In addition, the Bland-Altman analysis was applied in order to perform pairwise comparisons.Average WTW values obtained by the IOLMaster 700, the A…

AdultMaleWhite to whitebusiness.industryOcular surgerySiriusBiomedical EngineeringOphthalmologic Surgical ProceduresGeneral MedicineMiddle AgedYoung Adult03 medical and health sciences0302 clinical medicinemedicine.anatomical_structureAtlas (anatomy)030221 ophthalmology & optometrymedicineHumansOptometryFemaleSurgerybusiness030217 neurology & neurosurgeryOphthalmologic Surgical ProcedureDemographyExpert Review of Medical Devices
researchProduct

Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices.

2014

Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D). Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera) and the Pentacam HR (single Scheimpflug camera) systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured…

InterferometriaAdultAnterior ChamberScheimpflug principlePhotography/methodsPupil diameterIrisPupila/fisiologiaDiagnostic Techniques OphthalmologicalAnterior chamber anglePupilYoung AdultOpticsAnterior chamber/pathologyImaging Three-Dimensionallcsh:OphthalmologymedicineDiagnostic techniques ophthalmologicalPhotographyHumansPentacam hrDioptrePhysicsWhite to whitemedicine.diagnostic_testbusiness.industryPupilGeneral MedicineTécnicas de diagnóstico oftalmológicoCorneal topographyeye diseasesOphthalmologyInterferometryCâmara anterior/patologialcsh:RE1-994Fotografia/métodosTopografia da córneasense organsCorneal topographyPupil/physiologybusinessNuclear medicineArquivos brasileiros de oftalmologia
researchProduct

Device interchangeability on anterior chamber depth and white-to-white measurements: a thorough literature review

2016

We have reviewed a set of recently published studies that compared the anterior chamber depth (ACD) and/or white-to-white (WTW) distance obtained by means of different measuring devices. Since some of those studies reached contradictory conclusions regarding device interchangeability, this review was carried out in attempting to clarify which clinical devices can or cannot be considered as interchangeable in clinical practice to measure ACD and/or WTW distance, among these devices: A-scan, ultrasound biomicroscopy, Orbscan and Orbscan II (Bausch&Lomb Surgical Inc., San Dimas, California, USA), Pentacam and Pentacam HR (Oculus, Wetzlar, Germany), Galilei (Ziemer, Switzerland), Visante optica…

White to whitemedicine.medical_specialtybusiness.industryReviewClinical Practice03 medical and health sciencesOphthalmologyAlcon LaboratoriesAnterior chamber eye0302 clinical medicineOphthalmology030221 ophthalmology & optometryMedicineOptometryOrbscan iiPentacam hrbusiness030217 neurology & neurosurgeryInternational Journal of Ophthalmology